PZH HGS 100 Ex

Koda: 7710201

PZH HGS 100 Ex

Koda: 7710201

High power gas discharge tubes marked with Ex are suitable for use in explosion hazardous areas, where ensure the equipotential bonding between inactive parts, which are not conductively interconnected due to the operating conditions. Recommended for insulated flanges and insulated screw joints bridging in cathodic protected parts of industrial technology. In case of origin of potential difference between those parts, the high power gas discharge tube ignites and interconnects both insulated parts for a transient time. High protection degree of the housing allows using indoors, outdoors and also in the underground. Suitable construction prevents the formation of sparks and minimizes the release of heat generated during the discharge of the highest lightning impulse current.

TEHNIČNI PODATKI IN STANDARDI

OZNAKE V KATALOGU


MATERIALI


OZNAKA
MATERIAL
Rf
nerjaveče jeklo
Rf*H4
kislinsko odporno nerjaveče jeklo
Cu
baker
Al
aluminij
Fe
jeklo
FeZn
pocinkano jeklo
FeZn-H
vroče cinkano jeklo
KFe
kaljeno jeklo
FeCu
pobakreno jeklo
Me
medenina
PE
polietilen - UV stabilen
N
najlon – UV stabilen
P-SV
poliester, ojačan s steklenimi vlakni UV
pvc
elektrostatično plastificirano
PVC
odporna umetna masa
Les
les
Beton
beton
Ltž
lito železo
CuSn
pokositrani baker
PP
polypropylen

STRELOVODNA OPREMA

DIMENZIJE VODNIKA

(primernost nosilcev za določen profil vodnika)

OZNAKA
POMEN
Φ

premer okroglega vodnika

P

dimenzije preseka ploščatega vodnika

SISTEM PRITRJEVANJA VODNIKA NA NOSILEC

OZNAKA
POMEN
N

pritrjevanje z nylon pritrdilnim elementom

PE

pritrjevanje s polietilen pritrdilnim elementom

K
pritrjevanje s klik sistemom
V
pritrjevanje z vijačenjem
*
po naročilu


KABELSKE POLICE IN LESTVE

PODROČJE UPORABE

RAZRED
POMEN
N

kabelske police in lestve primerne za normalno uporabo

M

kabelske police in lestve s povečano stopnjo nosilnosti

H

kabelske police in lestve primerne za ekstremna področja uporabe

Legenda oznak

High power gas discharge tubes marked with Ex are suitable for use in explosion hazardous areas, where ensure the equipotential bonding between inactive parts, which are not conductively interconnected due to the operating conditions. Recommended for insulated flanges and insulated screw joints bridging in cathodic protected parts of industrial technology. In case of origin of potential difference between those parts, the high power gas discharge tube ignites and interconnects both insulated parts for a transient time. High protection degree of the housing allows using indoors, outdoors and also in the underground. Suitable construction prevents the formation of sparks and minimizes the release of heat generated during the discharge of the highest lightning impulse current.