PZH HDTNV2/48B

Koda: 77756009

PZH HDTNV2/48B

Koda: 77756009

PZH HDTNV*/*B is a complex range of surge protection devices designed for the protection of data, communication, measuring and control lines against surge effects. These devices are recommended for use at the boundaries of LPZ 1-2-3 lightning protection zones according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to EN 61643-21. The rated load current of individual protected lines IL = 1,5 A. 1st stage is solved by using three-pole gas discharge tubes, 2nd stage by using transils. The number of protected pairs is optional (1-2). PZH HDTNV*/*B is produced for nominal operating voltage within the range of 6V - 48 V.

TEHNIČNI PODATKI IN STANDARDI

OZNAKE V KATALOGU


MATERIALI


OZNAKA
MATERIAL
Rf
nerjaveče jeklo
Rf*H4
kislinsko odporno nerjaveče jeklo
Cu
baker
Al
aluminij
Fe
jeklo
FeZn
pocinkano jeklo
FeZn-H
vroče cinkano jeklo
KFe
kaljeno jeklo
FeCu
pobakreno jeklo
Me
medenina
PE
polietilen - UV stabilen
N
najlon – UV stabilen
P-SV
poliester, ojačan s steklenimi vlakni UV
pvc
elektrostatično plastificirano
PVC
odporna umetna masa
Les
les
Beton
beton
Ltž
lito železo
CuSn
pokositrani baker
PP
polypropylen

STRELOVODNA OPREMA

DIMENZIJE VODNIKA

(primernost nosilcev za določen profil vodnika)

OZNAKA
POMEN
Φ

premer okroglega vodnika

P

dimenzije preseka ploščatega vodnika

SISTEM PRITRJEVANJA VODNIKA NA NOSILEC

OZNAKA
POMEN
N

pritrjevanje z nylon pritrdilnim elementom

PE

pritrjevanje s polietilen pritrdilnim elementom

K
pritrjevanje s klik sistemom
V
pritrjevanje z vijačenjem
*
po naročilu


KABELSKE POLICE IN LESTVE

PODROČJE UPORABE

RAZRED
POMEN
N

kabelske police in lestve primerne za normalno uporabo

M

kabelske police in lestve s povečano stopnjo nosilnosti

H

kabelske police in lestve primerne za ekstremna področja uporabe

Legenda oznak
PZH HDTNV*/*B is a complex range of surge protection devices designed for the protection of data, communication, measuring and control lines against surge effects. These devices are recommended for use at the boundaries of LPZ 1-2-3 lightning protection zones according to EN 62305. All types provide effective protection of connected equipment against common mode and differential mode surge effects according to EN 61643-21. The rated load current of individual protected lines IL = 1,5 A. 1st stage is solved by using three-pole gas discharge tubes, 2nd stage by using transils. The number of protected pairs is optional (1-2). PZH HDTNV*/*B is produced for nominal operating voltage within the range of 6V - 48 V.
ISO9001_&_ISO14001_slo.pdf
Naziv spletne strani

Hermi, d.o.o.

Trnoveljska cesta 15

3000 Celje

Slovenija