Decoupling inductors are intended for rated load currents within the range of 63 and 80A. These inductors, sometimes also called decoupling impedance, ensure the energy coordination between the arresters type 1 and type 2 or the arresters type 2 and type 3 according to IEC 1024-1 and IEC EN 61643-11, especially in the places where there is no adequate distance between the arresters (e.g. when there are two successive arrester types placed in one switchboard). If the energy coordination of surge protection is not achieved, the lightning current impulse can damage some arrester type of the protection cascade. If there is at least 5m distance between two successive arrester types (in case of two successive arrester types in two different switchboards), this section impedance can be considered as adequate.

TEHNIČNI PODATKI IN STANDARDI

OZNAKE V KATALOGU


MATERIALI


OZNAKA
MATERIAL
Rf
nerjaveče jeklo
Rf*H4
kislinsko odporno nerjaveče jeklo
Cu
baker
Al
aluminij
Fe
jeklo
FeZn
pocinkano jeklo
FeZn-H
vroče cinkano jeklo
KFe
kaljeno jeklo
FeCu
pobakreno jeklo
Me
medenina
PE
polietilen - UV stabilen
N
najlon – UV stabilen
P-SV
poliester, ojačan s steklenimi vlakni UV
pvc
elektrostatično plastificirano
PVC
odporna umetna masa
Les
les
Beton
beton
Ltž
lito železo
CuSn
pokositrani baker
PP
polypropylen

STRELOVODNA OPREMA

DIMENZIJE VODNIKA

(primernost nosilcev za določen profil vodnika)

OZNAKA
POMEN
Φ

premer okroglega vodnika

P

dimenzije preseka ploščatega vodnika

SISTEM PRITRJEVANJA VODNIKA NA NOSILEC

OZNAKA
POMEN
N

pritrjevanje z nylon pritrdilnim elementom

PE

pritrjevanje s polietilen pritrdilnim elementom

K
pritrjevanje s klik sistemom
V
pritrjevanje z vijačenjem
*
po naročilu


KABELSKE POLICE IN LESTVE

PODROČJE UPORABE

RAZRED
POMEN
N

kabelske police in lestve primerne za normalno uporabo

M

kabelske police in lestve s povečano stopnjo nosilnosti

H

kabelske police in lestve primerne za ekstremna področja uporabe

Legenda oznak
Decoupling inductors are intended for rated load currents within the range of 63 and 80A. These inductors, sometimes also called decoupling impedance, ensure the energy coordination between the arresters type 1 and type 2 or the arresters type 2 and type 3 according to IEC 1024-1 and IEC EN 61643-11, especially in the places where there is no adequate distance between the arresters (e.g. when there are two successive arrester types placed in one switchboard). If the energy coordination of surge protection is not achieved, the lightning current impulse can damage some arrester type of the protection cascade. If there is at least 5m distance between two successive arrester types (in case of two successive arrester types in two different switchboards), this section impedance can be considered as adequate.