PZH R3 C/S

Koda: 7732007

PZH R3 C/S

Koda: 7732007

Surge arresters type T3 intended for use in installation and floor boxes and cable trays. Additional protection of socket circuits supplying devices with sensitive electronics. Additional protection of industrial socket circuits equipped with surge protection and a high-frequency filter (PZH HF, PZH HF3). Installed at the boundaries of LPZ 2 – LPZ 3, as close as possible to the protected device (no further than 5 m). In front of PZH R3 C/S must be installed a lightning current and surge arrester T1 and T2 from HERMI company. The protection devices offer a high discharge capacity in the surge arrester category T3, with UOC 6 kV / In 3 kA. Application standards: IEC 62305:2010, HD 60364-5-53:2022, CLC/TS 61643-12:2009.

TEHNIČNI PODATKI IN STANDARDI

OZNAKE V KATALOGU


MATERIALI


OZNAKA
MATERIAL
Rf
nerjaveče jeklo
Rf*H4
kislinsko odporno nerjaveče jeklo
Cu
baker
Al
aluminij
Fe
jeklo
FeZn
pocinkano jeklo
FeZn-H
vroče cinkano jeklo
KFe
kaljeno jeklo
FeCu
pobakreno jeklo
Me
medenina
PE
polietilen - UV stabilen
N
najlon – UV stabilen
P-SV
poliester, ojačan s steklenimi vlakni UV
pvc
elektrostatično plastificirano
PVC
odporna umetna masa
Les
les
Beton
beton
Ltž
lito železo
CuSn
pokositrani baker
PP
polypropylen

STRELOVODNA OPREMA

DIMENZIJE VODNIKA

(primernost nosilcev za določen profil vodnika)

OZNAKA
POMEN
Φ

premer okroglega vodnika

P

dimenzije preseka ploščatega vodnika

SISTEM PRITRJEVANJA VODNIKA NA NOSILEC

OZNAKA
POMEN
N

pritrjevanje z nylon pritrdilnim elementom

PE

pritrjevanje s polietilen pritrdilnim elementom

K
pritrjevanje s klik sistemom
V
pritrjevanje z vijačenjem
*
po naročilu


KABELSKE POLICE IN LESTVE

PODROČJE UPORABE

RAZRED
POMEN
N

kabelske police in lestve primerne za normalno uporabo

M

kabelske police in lestve s povečano stopnjo nosilnosti

H

kabelske police in lestve primerne za ekstremna področja uporabe

Legenda oznak

Surge arresters type T3 intended for use in installation and floor boxes and cable trays. Additional protection of socket circuits supplying devices with sensitive electronics. Additional protection of industrial socket circuits equipped with surge protection and a high-frequency filter (PZH HF, PZH HF3). Installed at the boundaries of LPZ 2 – LPZ 3, as close as possible to the protected device (no further than 5 m). In front of PZH R3 C/S must be installed a lightning current and surge arrester T1 and T2 from HERMI company. The protection devices offer a high discharge capacity in the surge arrester category T3, with UOC 6 kV / In 3 kA. Application standards: IEC 62305:2010, HD 60364-5-53:2022, CLC/TS 61643-12:2009.

Trenutno ni na voljo datotek v vašem jeziku

Naziv spletne strani

Hermi, d.o.o.

Trnoveljska cesta 15

3000 Celje

Slovenija